Part Number Hot Search : 
B350HD RED600 100LVEL 051233 04300 ISPLSI 1N4749AP TL431M
Product Description
Full Text Search
 

To Download 39-0304000 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 DMS-EB2
Multi-Purpose Application Board for DMS-20PC/LCD Meters
FEATURES
Gain (span) adjustment Input divider network for attenuating voltages up to 250Vdc Operate meter and board from +5V supply or 9/12V battery On-board solder gaps for decimal point placement On-board I/O connector for easy power and signal input
The DMS-EB2 Application Board was designed for quick and easy application/evaluation of DATEL's subminiature DMS-20PC/LCD Series, 31/2 Digit, LED/LCD Display, Digital Panel Voltmeters. The DMS-EB2's versatility, low cost and direct DMS-20PC/LCD plug-in compatibility makes interfacing a breeze. The DMS-EB2 covers many common panelmeter applications while providing easy signal and power I/O terminations (via a standard MOLEX connector) and plug-in versatility when changing from one application to another. The DMS-EB2 has provisions for such common applications as input dividers for high input voltages, gain (span) adjustment, 9/12Vdc battery operation, and decimal point placement. The board permits direct signal I/O wiring via the interface connector or soldering directly to the board. The DMS-EB2 is fully compatible with all four versions of the DMS20PC/LCD (200mV, 2V, 20V, 200V) making it interchangeable from meter to meter and application to application. Solder gaps 12 1 R1 SG10 are conveniently placed on the board and R2 may be quickly bridged or cut as required. SG14 SG6 SG5 SG4 This low-cost addition to DATEL's expanding line of subminiature meters demR5 C1 +C2 U1 onstrates our continuing commitment to offer J1 the most versatile, easy-to-use panel-meter products. SG15
J2 1 2 3 4 5 6 SG2 SG3 SG1
For full details go to www.murata-ps.com/rohs
Figure 1. DMS-EB2 Schematic Diagram
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-EB2.E01 Page 1 of 4
DMS-EB2
Multi-Purpose Application Board for DMS-20PC/LCD Meters
Functional Specifications (TA = 25C)
Input Supply Range See applicable meter's data sheet Input Supply Range U1 (LM7805CT) Installed: DMS-20PC-X-XS DMS-20PC-X-XL DMS-20LCD-X-5 DMS-20LCD-X-5B Operating and Storage Temperature See applicable meter's data sheet Humidity Dimensions J1 Connector & Wire Information Terminal Type Crimp Tool Wire Size Insulation Diameter Stripping Length DATEL P/N 39-2099090 DATEL P/N 39-2099000 22 to 26 AWG 0.062" (1.57mm) max. 0.100" to 0.125" (2.54 to 3.17mm) 0 to 95%, non-condensing 1.25" (31.8mm)L x 0.75" (19.1mm)H +7.5 to +12.6V +7.5 to +32.0V +7.5 to +32.0V +7.5 to +12.6V A 10F/35V tantalum capacitor (C2 on schematic) should be installed with the polarized end next to the + symbol on the DMS-EB2. This is especially important if the power source is located far from U1. 5. Soldering: DATEL recommends the use of "no-clean" solders when making modifications to the DMS-EB2.
APPLICATIONS
As shipped, the DMS-EB2 is configured for single-ended operation. This configuration is preferred for simple voltage measurements and will generally cover most standard applications. Figure 1 indicates which solder gaps are shipped closed from the factory. Simply solder the board onto the meter (pin 1 to pin 1), connect the power supply to J1, pin 5 (+V) and the power return to J1, pin 6 (GROUND).
Pin Function 1 (+) INPUT HI 2 (-) INPUT LO
J1
Ordering Information
DMS-EB2 DMS-BZL3 DMS-BZL4 39-0304000 39-2359625 Application board with mating connector and terminals DMS-20 bezel assembly DMS-20 bezel assembly with sealing gasket LM7805CT (U1), +5V-output, three-terminal regulator 6-position pc-board socket
3 TEST/HOLD IN 4 TEST/HOLD OUT 5 +V (Positive power connection)
6 -V (Ground, negative power return)
1
2
3
4
5
6
Figure 2. J1 Connector Pinout
TECHNICAL NOTES
1.LCD Backlighting: To backlight a DMS-20LCD meter, connect J1, pin 3 (TEST/HOLD IN) to J1, pin 6 (GND). This allows for external control, via a switch, of the backlight feature. The switch should be rated for low voltage operation at 35mA. 2. 9V LCD Meters: DMS-20LCD-X-9 meters cannot be used in a singleended configuration, i.e., with (-) IN LO tied to GND. On these models, both (-) IN LO and (+) IN HI have to be a minimum of 1.5V above and 1.5V below J1 pins 6 and 5, respectively. To operate from a 9V or 12V battery with (-) IN LO tied to GND, use a 5V-powered meter (DMS20LCD-X-5), install U1 (LM7805CT) and open SG4. 3. Input Resistor Dividers: Always use 1%, or better, metal-film resistors for R1 and R2, and also make sure their power and voltage ratings are adequate for the given application. 4. Using U1 (LM7805CT): The input power range specified in the Battery Operation section is rated conservatively assuming a 100mA LED meter or a 35mA backlit LCD meter. If a non-backlit LCD model or the lowpower LED model is used, the input voltage range can be extended up to 32Vdc.
1.Decimal Point Placement: DATEL ships the DMS-EB2 with all decimal point solder gaps (SG1, SG2 and SG3) open. To enable a specific decimal point, close its respective solder gap with solder. When re-assigning decimal places for subsequent applications, remember to unsolder previously closed solder gaps. Close SG1 for 1.999 (DP1) Close SG2 for 19.99 (DP2) Close SG3 for 199.9 (DP3) 2. Display Test (Not Available on LCD Models): Tie pin 4 (TEST/HOLD OUT) to pin 3 (TEST/HOLD IN) to test the display of the DMS-20PC. Do not leave the meter in the test mode for more than 10 seconds. On LED meters with the HOLD option, tying pins 3 and 4 together freezes the display reading. 3. Battery Operation: Open SG4 and install U1 (LM7805CT) with its metal tab facing to the left as shown in Figure 3. Allowable input power ranges (J1, pins 5 and 6) are as follows: DMS-20PC-X-XS +7.5 to +12.6Vdc DMS-20PC-X-XL +7.5 to +32Vdc C2 (10F/35V) can be added to reduce noise. Observe correct polarity. Refer to Technical Note 4 for more information.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-EB2.E01 Page 2 of 4
DMS-EB2
Multi-Purpose Application Board for DMS-20PC/LCD Meters
R1
1 U1
TO-3-style tab points to left
12 R3
SG10
To measure input voltages greater than 100Vdc, open SG10 and also cut these two etch paths.
SG1
Figure 4. Installing R1
SG2
SG3
Figure 3. Installing U1
4. Calibrate the meter using a known voltage source. Adjust the internal gain potentiometer to compensate for variations in R1 and R2. Example VIN is 199.9Vdc, and the display reading must be "199.9". 1. Assume R1 = 1.0M 2. R2 = (FSI x R1) / ( |VIN| - FSI) R2 = (1.999 x 1,000,000) / (199.9 - 1.999) R2 = 10101.01 or 10k 7. Current Measurements (Use 200mV Model, DMS-20PC/LCD-0): The following instructions are for measuring current derived from the DMS20PC/LCD's power source. When measuring current that is floating with respect to J1, pin 6 (GROUND), leave SG5 closed. CAUTION: Do not exceed 1 Ampere input current. 1. Install R2 (R2 = FSR / (IMAX x 10000)) where FSR is the desired reading (0 -1999) and IMAX is between 0 -1 Ampere. 2. Open SG5. 3. Apply input signal (current) to (+)IN HI and (-) IN LO. 4. Adjust internal gain pot for desired full scale readings. 5. Enable decimal points using either SG1, SG2 or SG3. Example A 1.0 Ampere input must read "1.000" on the display. R2 = 1000 / (1 x 10000) R2 = 0.1 Ohm Enable DP1 via SG1 for reading of 1.000 8. Displaying DMS-20PC/LCD's Power Source (Use DMS-20PC/LCD-2, 5V-Powered Models Only): 1. If the power source is higher than 5Vdc, be sure to install U1 and cut SG4. See Battery Operation section and Technical Note 4. 2. Solder a short piece of jumper wire across the two holes labeled J2. 3. Close SG2 to enable DP2.
4. Calibration Adjustment: The DMS-EB2 has provisions for adjusting the calibration of the DMS-20 meter. Calibration adjustment is useful when an input divider (using R1 and R2) is necessary to scale the input voltage. The calibration potentiometer allows "tweaking" of the display reading. Using the calibration potentiometer Adjust the calibration pot on the back of the meter as desired. The adjustment range is only 3/4 of a turn. Do not force the pot past its end stops. 5. Differential Input Signals (Signal Referenced to Power Source): Open SG5. Apply the input signal to pin 1, (+) IN HI, and pin 2, (-) IN LO, of J1. NOTE: Common mode voltage must not exceed 2Vdc. 6. Measuring Input Voltages Greater than 1.999Vdc (Use DMS-20PC/ LCD-1 Only): CAUTION: Do not exceed 250Vdc input signal. 1. Open SG10. For applications in which input voltages exceed 100Vdc, also cut the 2 adjoining traces. 2. Calculate values for R1 and R2 as follows: R2 = (FSI x R1) / ( |VIN| - FSI) Where: FSI = The attenuated voltage, between the meter's (-) IN LO and (+) IN HI pins, needed to achieve the desired display readings VIN = Input voltage at J1 (beween pins 1 and 2) A typical value for R1 is 1M . The sum of R1 + R2 should be between 50k and 10M . 3. Enable DP3 by soldering SG3.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPM_DMS-EB2.E01 Page 3 of 4
DMS-EB2
Multi-Purpose Application Board for DMS-20PC/LCD Meters
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
11/10/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
www.murata-ps.com
MPM_DMS-EB2.E01 Page 4 of 4


▲Up To Search▲   

 